Modern Heating Manifolds: The Central Component of Efficient Underfloor Heating

A heating manifold connects the heat source (such as a heat pump or boiler) to the individual heating circuits of an underfloor or surface heating system. It distributes the flow of hot water to different rooms and collects the cooled return water. This ensures even heat distribution throughout the building without unnecessary losses. Without the manifold, some rooms would be too warm while others remain too cold. A properly adjusted manifold is therefore crucial for both comfort and energy efficiency.

Flow Meters for Precise Control

Modern stainless-steel manifolds feature integrated flow meters on each supply line. These indicators display the actual water flow rate for every heating circuit and can be precisely adjusted. This allows the installer to fine-tune the flow in each room during hydraulic balancing. It prevents short or nearby circuits from being over-supplied while others remain underheated. Only with the correct flow rate does every room reach the desired temperature — otherwise, the entire system would need to run at a higher supply temperature, wasting energy.

Durchflussanzeiger eines Heizkreisverteilers, 0-5 l/min
Heizkreisverteiler mit Kugelhähnen und integrierten Temperaturanzeigen

Ball Valves with Thermometers

Instead of rigid shut-off valves, our manifolds use ball valves with integrated thermometers. These combine reliability (shut-off function) with temperature monitoring. The small thermometers on the supply and return lines immediately display the temperature of each circuit. This allows you to check whether the temperature difference (Delta-T) is within the target range or if a circuit is returning too cold. Flow and return temperatures can thus be perfectly matched. This way, you always have a precise view of the current system temperatures directly inside the manifold box, without any extra effort.

Automatic Air Vents for Trouble-Free Operation

Air inside the heating system disrupts heat transfer and wastes energy: air pockets in the circuits reduce water flow and force the pump to work harder, increasing electricity use and causing uneven operation. Our manifolds are therefore equipped with automatic air vents. These compact valves continuously remove trapped air from the system, ensuring smooth operation. They prevent air bubbles from blocking circulation or overloading the pump. As a result, the underfloor heating remains fully water-filled, quiet, and consistently efficient.

Heizkreisverteiler mit automatischem Entlüfter für die Fußbodenheizung

Stainless Steel as a Material: Corrosion Protection and Durability

High-quality manifolds are usually made of stainless steel. Stainless steel – especially our premium 304 stainless grade – is known for its excellent resistance to corrosion. This ensures that the heating manifold remains reliably protected and fully functional even with continuous contact with heating water. In practice, stainless steel has proven to be a dependable material in heating circuits for many years. Even when combined with copper or brass fittings, no harmful galvanic corrosion occurs. Compared to plastic housings, stainless steel offers significantly greater stability under pressure and temperature. A stainless steel manifold remains free from pitting or rust under normal heating water conditions. In addition, stainless steel bars and pipes do not deform, lose their strength, or deteriorate over time – and are far more recyclable.

Additional advantages: maintenance, durability and balancing

Our stainless steel manifolds are not only highly durable but also designed for low maintenance. With integrated flow indicators, automatic air vents and ball valves with thermometers, you always have a clear overview of your system’s performance. This configuration allows easy monitoring of flow, temperature and air release without additional maintenance effort. Stainless steel ensures long service life and reliable corrosion protection even during continuous operation.

The integrated measuring and control technology makes hydraulic balancing much easier. The flow rate of each heating circuit can be precisely adjusted, ensuring even heat distribution throughout all rooms. This keeps the system running efficiently and comfortably at all times, while clear flow and temperature readings simplify commissioning and inspection for professionals.

Professional planning and installation: To fully benefit from all these advantages, heating manifolds should always be planned and installed by a qualified professional. This ensures that each heating circuit is properly balanced and matched to the specific heat demand of each room. A professionally installed stainless steel manifold with flow indicators, thermometers and automatic air vents guarantees maximum efficiency, comfort and long-term energy savings.

Heating circuit distributor overview table
Edelstahl Heizkreisverteiler 3 Heizkreise3 heating circuits
94,00€
In stock
Edelstahl Heizkreisverteiler 4 Heizkreise4 heating circuits
114,00€
In stock
Edelstahl Heizkreisverteiler 5 Heizkreise5 heating circuits
129,00€
In stock
Edelstahl Heizkreisverteiler 6 Heizkreise6 heating circuits
134,00€
Out of stock
Edelstahl Heizkreisverteiler 7 Heizkreise7 heating circuits
149,00€
In stock
layers Heating circuits 3 4 5 6 7
straighten max. Size
(Length x Width x Height)
L: 320 mm
W: 107 mm
H: 315 mm
L: 370 mm
W: 107 mm
H: 315 mm
L: 420 mm
W: 107 mm
H: 315 mm
L: 470 mm
W: 107 mm
H: 315 mm
L: 520 mm
W: 107 mm
H: 315 mm